User profiles for Y. Rozov

Розов В. Ю. , Rozov V. Yu., Rozov V, Rozov V. Y, Володимир Розов, Volodymyr Rozov.

Інститут проблем машинобудування ім. А. М. Підгорного НАН України
Verified email at nas.gov.ua
Cited by 784

Flowing sand: A physical realization of directed percolation

H Hinrichsen, A Jiménez-Dalmaroni, Y Rozov… - Physical Review Letters, 1999 - APS
We introduce and investigate a simple model to describe recent experiments by Douady
and Daerr on flowing sand. The model reproduces experimentally observed compact …

METHOD OF CALCULATING THE MAGNETIC FIELD OF THREE-PHASE POWER LINES.

VY Rozov, SY Reutskyi… - Technical …, 2014 - search.ebscohost.com
The method of calculation of the magnetic field (MF) of three-phase transmission lines (TL)
is proposed. It allows to make the calculation and hygienic assessment of the effective value …

Simulation of electromagnetic field in residential buildings located near overhead lines

VY Rozov, VS Grinchenko, DY Pelevin… - Технiчна …, 2016 - elibrary.ru
This paper deals with the numerical simulation of power frequency electromagnetic field in
the multi-storey building which is made of precast concrete and is located near the overhead …

[HTML][HTML] Efficient shielding of three-phase cable line magnetic field by passive loop under limited thermal effect on power cables

VY Rozov, VS Grinchenko, AV Yerisov… - Электротехника и …, 2019 - cyberleninka.ru
This paper deals with a mitigation of a three-phase cable line magnetic field by a new type
of passive shield. We consider a cable line with a flat arrangement of cables. The developed …

[HTML][HTML] Active shielding of external magnetic field of built-in transformer substations

VY Rozov, KD Kundius, DY Pelevin - Электротехника и …, 2020 - cyberleninka.ru
This paper deals with the mitigation of low-frequency magnetic field of build-in transformer
substations down to the reference level 0.5 μT in nearby living spaces. To meet the reference …

Digital acoustic signal processing methods for diagnosing electromechanical systems

…, I Kondratieva, Y Rozov, Y Lebedenko - Lecture Notes in …, 2020 - Springer
An effective means of preventing accidents, identifying critical operating modes, and
diagnosing equipment failures of electromechanical systems are the methods of functional …

[PDF][PDF] Simulation of the magnetic field in residential buildings with built-in substations based on a two-phase multi-dipole model of a three-phase current conductor.

VY Rozov, DY Pelevin, KD Kundius - Electrical Engineering & …, 2023 - eie.khpi.edu.ua
Problem. Substations 10 (6)/0.4 kV built into residential buildings create a magnetic field with
magnetic flux density of more than 10 μT in nearby residential premises, which is a danger …

[PDF][PDF] Approximate method for calculating the magnetic field of 330-750 kV high-voltage power line in maintenance area under voltage

VY Rozov, SY Reutskyi, DY Pelevin… - Electrical Engineering …, 2022 - eie.khpi.edu.ua
Problem. In order to organize effective protection of working personnel from the action of
strong electromagnetic influence when performing work on live high-voltage power lines (HVPL)…

[HTML][HTML] External magnetic field of urban transformer substations and methods of its normalization

VY Rozov, DY Pelevin, KD Pielievina - Электротехника и …, 2017 - cyberleninka.ru
Rozov V.Yu. Vneshnie magnitnye polia silovogo elektrooborudovaniia i metody ikh umen'sheniia
[External magnetic fields of power electrical equipment and methods for reducing them]…

Flowing sand—a possible physical realization of Directed Percolation

H Hinrichsen, A Jiménez-Dalmaroni, Y Rozov… - Journal of Statistical …, 2000 - Springer
A simple model for flowing sand on an inclined plane is introduced. The model is related to
recent experiments by Douady and Daerr and reproduces some of the experimentally …